Component Descriptions

Part Component Function
1 Isolation valve to isolate the installation from the steam supply
2 Separator to protect the installation from wet steam
3 Strainer to protect the control valve from detritus
4 Hi-limit Control Valve to protect the installation from overtemperature
5 Pressure Gauge to monitor the steam supply pressure
6 Pressure Reducing Valve to reduce pressure to the system
7 Pressure Gauge to monitor the reducing valve set pressure
8 Safety Valve to protect the downstream equipment from overpressure
9 Isolation Valve to monitor the set pressure of the reducing valve
10 Vacuum Breaker to assist condensate removal from the heater at stall conditions
11 Air Vent to vent air from the heat exchanger steam supply
12 Isolation Valve to isolate the air vent & vacuum breaker from the steam supply
13 - 17 inc. Separator Steam Trap Set  
18 Hi-limit Cut Out to close the hi-limit valve shut on overtemperature
19 Hi-limit Sensor to sense the secondary water for overtempertaure
20 Temperature Sensor to sense the secondary water for temperature
21 Isolation Valve to isolate the secondary flow from the heat exchanger
22 Electronic Controller to signal the control valve to move position
23 Pneumatic Actuator to drive the control valve
24 E/P Positioner to position the valve correctly at all loads
25 Balancing Valve to balance the flow in the bypass with the heat exchanger
26 Isolation Valve to isolate the secondary return from the heat exchanger
27 - 32 inc. Heat Exchanger Steam Trap Set  
33 Plate Heat Exchanger to heat the secondary liquid
Arrow Top
 

Table of Parts

Part   Component Bronze Cast iron SG iron Steel Stainless steel Product details
5, 7 Pressure Gauge 100 mm Diameter Pressure Gauge with 'U' or Ring Syphon Pipes Pressure Gauges & Temperature Gauges
24 Positioner SP200 Electropneumatic Positioner Positioners, Controllers & Sensors
23 Pneumatic Actuator PN9000 Series Pneumatic Actuator Pneumatic Actuators
29 Control Valve     KE71 KE71B   Control Valves
8 Safety Valve SV615 SV73       Safety Valves
22 Electronic Controller SX25, SX75 Series Controller Positioners, Controllers & Sensors
2 Separator   S2 S1 S5   Separators & Insulation Jackets
1, 9 Bellows Sealed Stop Valve       A3S   Bellows Sealed Stop Valves
3, 16, 31 Strainer Fig 12   Fig 12 Fig 14 Fig 16 or 16L Strainers & Filters
6 Pressure Reducing Valve     DP27     Pressure Reducing & Surplussing Valves
11 Air Vent AV13     AVC32   Air Vents & Air Eliminators
10 Vacuum Breaker VB14       VB21 Vacuum Breakers
4 Control Valve SB, KA51, KC51 or KB51 KC31, KA31 or KB31       Self-acting Controls or Control Valves
18 High Limit Cut-out HL10 High Limit Cut-out Self-acting Controls
19 Control System Type 130 Control System Control Valves
20 Temperature Sensor EL2200 Temperature Sensor Control Valves
14, 28 Lift Check Valve LCV1     LCV2   Check Valves
12, 13, 17, 21, 26, 27, 32 Ball Valve (Screwed or Flanged)       M10 M10 Ball Valves
33 Plate Heat Exchanger           Ball Valves
25 Balancing Valve   BSA1T BSA2T BSA3T BSA6T Bellows Sealed Stop Valves