TDS Automatic Control

Continuous Monitoring - Steam Generators (Type BCS2)

Products used for automatic TDS control of coil boilers and steam generators.

Continuous Monitoring - Steam Generators (Type BCS2)
 

Component Descriptions

Part Component Function
1 Blowdown Controller to control the operation of the TDS control valve
2 Conductivity Sensor to monitor the conductivity of the blowdown water
3 TDS Control Valve to regulate the flow of the blowdown water to waste
4 Isolating Valve to isolate the blowdown line for maintenance
5 Strainer to protect the system from detritus
6 Ball Float Steam Trap to drain the separator of condensate
7 Isolating Valve to isolate the TDS control system from the blowdown line
8 Drain Valve to drain the separator for maintenance purposes
9 Vacuum Breaker to prevent back-syphoning of water from the feedtank
Arrow Top
 

Table of Parts

Part Component Spirax Sarco Reference Product details
1 Controller BC3100 Controller TDS Blowdown Controls
2 Sensor Chamber S20 Sensor Chamber with TP10 Temperature Sensor and CP10 TDS Sensor  
3 TDS Control Valve BCV1, BCV20 or BCV30 Blowdown Control Valve TDS Blowdown Controls
4, 7, 8 Isolating Valve M10 Ball Valve Ball Valve
5 Strainer Fig 1, 12, 12SG, 13, 14, 16 or 16L Strainer Strainers & Filters
6 Ball Float Steam Trap IFT Type Ball Float Steam Trap with Monitor Steam Trap Performance Monitoring
9 Vacuum Breaker VB14, VB21 Vacuum Breaker Vacuum Breakers

For more information on the BCS2 Blowdown Control System go to our TDS Blowdown Controls page.