Heat Exchangers
Plate Heat Exchanger with Active Drainage System
Draining condensate into a flooded condensate system with a mechanical pump and float trap.
Component Descriptions
| Part | Component | Function |
|---|---|---|
| 1 | Isolation valve | to isolate the installation from the steam and condensate systems |
| 2 | Separator | to protect the installation from wet steam |
| 3 | Pressure Gauge | to monitor the reducing valve set pressure |
| 4 | Control Valve | to protect the installation from overtemperature |
| 5 | Reducing Valve | to reduce pressure to the system |
| 6 | Pressure Gauge | to monitor the reducing valve set pressure |
| 7 | Air Regulator | to supply the positioner with air at the correct pressure |
| 8 | Electronic Controller | to signal the control valve to move position |
| 9 | Isolation Valve | to isolate the installation from the steam and condensate systems |
| 10 | Pneumatic Actuator | to drive the control valve |
| 11 | E/P Positioner | to position the valve correctly at all loads |
| 12 | Control Valve | to regulate the flow of steam to the heat exchanger |
| 13 | Safety Valve | to protect the downstream equipment from overpressure |
| 14 | Pressure Gauge | to monitor the reducing valve set pressure |
| 15 | Plate Heat Exchanger | to heat the secondary fluid from steam in the primary circuit |
| 16 | Hi Limit Control System | to control the hi-limit shut-off valve |
| 17 | Temperature Sensor | to sense the secondary water temperature |
| 18 | Ball Valve | to isolate the various systems |
| 19 | Disc Check Valve | to prevent backflow of fluid |
| 20 | Ball Float Steam Trap with Monitor | to remove condensate as and when it forms |
| 21 | Strainer | to protect the control valve from detritus |
| 22 | Ball Valve | to isolate the various systems |
| 23 | Hi-limit Cut-out | to close the hi-limit valve shut on overtemperature |
| 24 | Ball Valve | to isolate the various systems |
| 25 | Strainer | to protect the control valve from detritus |
| 26 | Ball Valve | to isolate the various systems |
| 27 | Disc Check Valve | to prevent backflow of fluid |
| 28 | Ball Float Steam Trap with Monitor | to remove condensate as and when it forms |
| 29 | Ball Float Steam Trap with Monitor | to remove condensate as and when it forms |
| 30 | Ball Valve | to isolate the various systems |
| 31 | Automatic Pump | to remove condensate under stall conditions |
| 32 | Disc Check Valve | to prevent backflow of fluid |
| 33 | Air Vent | to vent air from the pump system automatically |
| 34 | Isolation Valve | to isolate the installation |
| 35 | Disc Check Valve | to prevent backflow of fluid |
| 36 | Ball Float Steam Trap with Monitor | to remove condensate as and when it forms |
| 37 | Disc Check Valve | to prevent backflow of fluid |
| 38 | Ball Valve | to isolate the various systems |
| 39 | Pressure Gauge | to monitor the reducing valve set pressure |
| 40 | Ball Valve | to isolate the various systems |
Table of Parts
| Part | Component | Bronze | Cast iron | SG iron | Steel | Stainless steel | Product details | |
|---|---|---|---|---|---|---|---|---|
| 6, 14, 39 | Pressure Gauge | PG Pressure Gauge with 'U' or Ring Syphon Pipes | Pressure Gauges & Temperature Gauges | |||||
| 7 | Air Filter / Regulator | Spirax Monnier MPC2 High Efficiency Filter/Regulator Air Set | Filter/Regulators | |||||
| 11 | Positioner | SP200 Electropneumatic Positioner | Positioners, Controllers & Sensors | |||||
| 10 | Pneumatic Actuator | PN9000 Series Pneumatic Actuator | Pneumatic Actuators | |||||
| 12 | Control Valve | KE73 | KE43 | Control Valves | ||||
| 13 | Safety Valve | SV73 | SV607 | SV74, SV604 | SVL606 | Safety Valves | ||
| 8 | Electronic Controller | SX25, SX75 Series Controller | Positioners, Controllers & Sensors | |||||
| 2 | Separator | S3 | S5, S7 | S6, S8 | Separators & Insulation Jackets | |||
| 1, 9, 34 | Bellows Sealed Stop Valve | BSA1 | BSA2 | BSA3 | Bellows Sealed Stop Valves | |||
| 3, 21, 25 | Strainer (flanged) | Fig 3 | Fig 33 | Fig 37 | Fig 34 | Fig 36 | Strainers & Filters | |
| 5 | Pressure Reducing Valve | DP27 | Pressure Reducing & Surplussing Valves | |||||
| 4 | Control Valve | KA33 or KB33 | KA43, KB43 or KC43 | Control Valves | ||||
| 23 | High Limit Cut-out | HL10 High Limit Cut-out | Self-acting Controls | |||||
| 16 | Control System | Type 130 Control System | Control Valves | |||||
| 19 | High Limit Cut-Out | HL10 High Limit Cut-Out | Self-acting Controls | |||||
| 18 | Control System | Type 130 Control System | Self-acting Controls | |||||
| 17 | Temperature Sensor | EL2200 Temperature Sensor | Control Valves | |||||
| 18, 22, 24, 26, 30, 38, 40 | Ball Valve | M10 or M20 | M10 or M20 | Ball Valves | ||||
| 20, 28, 29, 36 | Ball Float Steam Trap with Monitor | IFT53 | IFT57 | IFT54 | Steam Trap Performance Monitoring | |||
| 19, 27, 32, 35, 37 | Disc Check Valve | DCV2, 3 or 4 | Check Valves | |||||
| 33 | Air Vent | AV13 | AVC32 | Air Vents & Air Eliminators | ||||
| 31 | Automatic Pump | MFP14 Automatic Pump | Pressure Powered Pumps | |||||
| 15 | Plate Heat Exchanger | Ball Valves | ||||||
What do I do now?
Spirax Sarco have experienced engineers available to offer advice on these applications:
Let us help you size and select these products
Arrange a visit to your plant by Spirax Sarco
Ask us a question about this application